Chinese name 混合戊烷
Chemical FormulaC5H12
Species1 80/20
Species2 60/40
Species3 50/50
Usage:
Pentane blends is mixed by npentane and isopentane by certain ratio, mainly used as blowing/expandable agent, for EPS foaming, etc.
Pentane 80/20 is a blend of 80% npentane and 20% iso pentane.
Pentane 60/40 is a blend of 60% npentane and 40% isopentane.
Pentane 50/50 is a blend of 50% npentane and 50% isopentane.
Customer-taliored grade is avaliable.
| Model | F1 | F2 | F3 | F4 | F5 | F6 | F7 | F8 | F9 |
| N-pentane/% | 10 | 20 | 30 | 40 | 50 | 60 | 70 | 80 | 90 |
| Iso-pentane/% | 90 | 80 | 70 | 60 | 50 | 40 | 30 | 20 | 10 |
Note: +2% is allowed
| Item | Unit | Spec of pentane 80/20 | Spec of pentane 60/40 | Spec of pentane 50/50 | Test Method |
|---|---|---|---|---|---|
| Appearance | – | Clear | Clear | Clear | Visual |
| Total-pentane | Wt% | ≥99 | ≥99 | ≥99 | GAS CHRO |
| N-pentane | Wt% | 78-82 | 58-62 | 48-52 | GAS CHRO |
| Iso-pentane | Wt% | 18-22 | 38-42 | 48-52 | GAS CHRO |
| heavier | Wt% | ≤0.1 | ≤0.1 | ≤0.1 | GAS CHRO |
| Butane and lighter | Wt% | ≤0.1 | ≤0.1 | ≤0.1 | GAS CHRO |
| Total Olefin | ppm | ≤20 | ≤20 | ≤20 | GAS CHRO |
| Aromatic content | ppm | ≤10 | ≤10 | ≤10 | GAS CHRO |
| Benzene | ppm | ≤1 | ≤1 | ≤1 | GAS CHRO |
| Nonvolatile | mg/100ml | ≤1 | ≤1 | ≤1 | ASTM D1353 |
| Total Sulfur | ppm | ≤1 | ≤1 | ≤1 | ASTM D5453 |
| Doctor test | – | Negative | Negative | Negative | ASTM D4952 |
| Bromine index | mgBr/100 | ≤1 | ≤1 | ≤1 | ASTM D2710 |
| Saybolt Color | – | 30 | 30 | 30 | ASTM D156 |
| Total Nitrogen | ppm | ≤1 | ≤1 | ≤1 | ASTM D6069 |
| Carbonyl | ppm | ≤1 | ≤1 | ≤1 | ASTM E411 |
| Copper corrosion | – | 1a | 1a | 1a | ASTM D130 |
| Residue Acid | – | Neutral | Neutral | Neutral | ASTM D1093 |
| Water | ppm | ≤20 | ≤20 | ≤20 | Karl-fisher |
| Density at 15°C | – | 0.615-0.630 | 0.615-0.630 | 0.615-0.630 | ASTM D4052 |
Transport information:
Packed in 24 cubic meters iso tank.
DOT Classification: Pentane, Flammable Liquid UN1265
High Flammable. Store in original containers in approved flame-proof area. Keep containers securely sealed. Store away from incompatible materials in a cool, dry well ventilated area. Protect containers against physical damage and check regularly for leaks. Read SDS carefully before handling.